Electromagnetic Compatibility (EMC)
In a connected world where devices and systems constantly interact with electromagnetic fields, EMC testing is essential. It ensures that your products not only function flawlessly, but also that they do not cause interference in their environment, whether in sensitive applications such as aviation or in medical technology. These tests minimize failures in the field, protect against legal repercussions, and guarantee smooth market access.
Our designated partner laboratories EMC-Testcenter in Regensdorf and emvlab in Zurich utilize high-precision infrastructure to conduct emission and immunity tests according to global standards.
Testing Technologies & Applications We Specifically Serve
- Information technology equipment (ITE) and multimedia devices
- Industrial, scientific, and medical equipment (ISM)
- Lighting equipment and similar electrical devices
- Railway applications (rolling stock and signaling/telecom)
- Alarm, intrusion, video surveillance, access control, and personal emergency call systems
- Home and building electronic systems (HBES) and building automation
- Automotive and defense/military systems
- Aviation and space applications
- Medical devices and environments
Main EMC Standards we cover:
Emission (Disturbance)
- EN 55011 / CISPR 11 – Industrial, scientific and medical equipment
- EN 55015 / CISPR 15 – Lighting equipment
- EN 55032 / CISPR 32 – Multimedia equipment
- IEC 61000-3-2 & IEC 61000-3-3 – Harmonic currents & voltage fluctuations/flicker
- IEC 61000-6-3 & IEC 61000-6-4 – Generic emission standards (residential & industrial)
- EN 50121 series – Railway applications
Immunity (Susceptibility)
- IEC 61000-4-2 – Electrostatic discharge (ESD)
- IEC 61000-4-3 – Radiated RF fields (up to 6 GHz)
- IEC 61000-4-4 – Electrical fast transients / burst
- IEC 61000-4-5 – Surge
- IEC 61000-4-6 – Conducted RF disturbances
- IEC 61000-4-8 – Power-frequency magnetic fields
- IEC 61000-4-11 – Voltage dips & short interruptions
- IEC 61000-6-1 & IEC 61000-6-2 – Generic immunity standards (residential & industrial)
- IEC 60601-1-2 – Medical electrical equipment
Additional Important Standards (depending on product and end-market)
- EN 50130-4 – Alarm systems
- IEC 63044 series – Home & building automation
- RTCA DO-160 / MIL-STD-461 – Aviation & defence
- EN 50121 series – Railway
- FCC Part 15 – USA market
Infrastructure
- Full Anechoic Chamber: 6.50 x 3.00 x 3.50 meter
- Anechoic Chamber 1: 8.50 x 5.00 x 5.50 meter
- Anechoic Chamber 2: 20.00 x 12.00 x 8.00 meter
Access doors 4.00 x 4.00 meter,
Floor load-bearing capacity 10t/m2 - Faraday Room 1: 5.00 x 4.00 x 3 meter
- Faraday Room 2: 5.00 x 5.00 x 3 meter
- Faraday Room 3: 5.00 x 3.00 x 3 meter
- Faraday Room 4: 5.00 x 4.00 x 3 meter
- Faraday Room for subsystems
- Monitoring and control room equipped with latest measurement and control devices